61
4.5 Serial/IP Advanced Settings
In the Serial/IP Control Panel, Click on the Advanced button to open Advanced Settings window (Figure 4.18). Click
on Use Default Settings to load the default settings.
Figure 4.18 Serial/IP Default Advanced Settings
Extend Server Connection
Maintains the TCP connection for specified amount of time after COM port is closed
Attempt Server Connection
Terminates pending connection attempts if they do not succeed in the specified time
Synchronize with Server Upon COM Port Open
Required by NT Systems (2000, XP, Vista, 7)
Update Routing Table Upon COM Port Open
Maintains IP route to a server in a different subnet by modifying the IP routing table
Enable Nagle Algorithm
Provides better network efficiency by imposing a minor latency on the data stream while it waits to fill network
packets
Always Limit Data Rate to COM Port Baud Rate
Limits the data rate to the baud rate that is in effect for the virtual COM port