Table of parameters, Telephone interface fxs parameters, 2 table of parameters – 2N Fixed line replacement with 2N SmartGate - Manual v1.1.2 User Manual
Page 30: Table of parameters 3.2, Dialing parameters
Table of Parameters
3.2
30
3.2 Table of Parameters
All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, function number (if avaliable) for programming via
a telephone line, description of SmartGate's behavior, setting options, setting step
and default (initialization) value.
Numeric parameters must be set in unit listed in the parameter description. For
parameters with different setting are values defined in the parameters description
(for phone line programming in parenthesis). When phone line programming is
used, character
can‟t be included in the string, because it is dedicated for
confirmation of the new parameter value.
Telephone interface FXS parameters
Dialing parameters
Type of dialing
Function No.: 100
Select the dialing type to be received by 2N® SmartGate on the FXS interface.
2N® SmartGate accepts only the selected type of dialing, ignoring the others.
Setting options:
DTMF (0) -2N® SmartGate receives tone dialing only.
Pulse (1) -2N® SmartGate receives pulse dialing only
Default setting:
DTMF
Timeout for dialing end recognize [s] Function No.: 101
Timeout during which 2N® SmartGate waits for further digits to be dialed. It
starts to establish connection when this timeout passes.
Setting options:
1-255 s
Setting step:
1 s
Default setting:
5 s
Minimal On Hook [ms]
Function No.: 102
The minimum line current break that 2N® SmartGate evaluates as hang-up.
Setting options:
100-25500 ms
Setting step:
100 ms
Default setting:
500 ms