JLG G6-23A Service Manual User Manual
Page 120

Electrical System
9.30
G5-19A, G6-23A
DATALOG:
ON
XXXXhXXm
Displays total controller on (power) time
LIFT
XXXXhXXm
Displays total controller lift operation
time
FORK TILT
XXXXhXXm
Displays total controller fork tilt
operation time
TELE
XXXXhXXm
Displays total controller telescope
operation time
AUX HYD
1/2
XXXXhXXm
Displays total auxiliary hydraulics 1 and
2 operation time
MAX VOLTS
XX.XV
Displays maximum measured battery
voltage
RENTAL
XXXXhXXm
Displays total controller operation time.
NOTE: can be reset
ERASE
RENTAL?
Not available at password level 2.
ENTER resets rental data log time to
zero
VERSION:
GM SW
PX.X
Displays ground module software
version
GM HW REV
XXXX
Displays ground module hardware
version
GM SN
XXXXXX
Displays ground module serial number
JYSTK SW
XX.X
Displays joystick software version
ANALYZER
VX.XXXX
Displays Analyzer software version
Diagnostics Submenu
(Displayed on Analyzer 1st
Line)
Parameter
(Displayed
on Analyzer
2nd Line)
Parameter Value
(Displayed on Analyzer
2nd Line)
Description