3.1 B
ATTERY CUTOUT SWITCH
This device, located on the left side of the electrical components compartment, is used to iso‑
late the machine’s electrical circuit, stopping any movements.
It is well‑visible and easily accessed without using tools. It only needs to be activated for pro‑
longed machine downtime or maintenance operations.
Turning the key clockwise closes the machine’s electrical circuit, while turning it anticlockwi‑
se isolates the machine’s electrical circuit and the key can be removed.
B
EFORE DISCONNECTING THE BATTERY BY MEANS OF THIS DEVICE
,
MAKE SURE THAT THE ENGINE
KEY IS IN POSITION
“
OFF
”,
THE RADIO CONTROL EMERGENCY STOP BUTTON HAS BEEN PRESSED AND
THE REMOTE CONTROL AND ELECTRONIC BOARD ARE OFF
.
3.2 D
ISTRIBUTOR PRESSURE RELIEF VALVES
All platform distributors have a pressure relief valve that limits the pressure inside the
system to the value set for the same valve.
These valves are calibrated in the platform inspection phase by qualified staff working and
must not be tampered with for any reason.
IMPORTANTE
X14JR0420113
38
BOOM LIFT MODELS X14J
JLG
IMPORTANT
THERMIC MOTOR
LITHIUM MOTOR