JLG X14J Operator Manual User Manual
Page 154

BATTERY CHARGER FAULT CODES
BOOM LIFT MODELS X14J
JLG
150
X14JR0420113
CODE
DESCRIPTION
STATUS
ACTION
8
Internal logic fault.
Battery charger stops working.
Contact service dept. or
change product.
13
Communication pro‑
blem with external
memory.
Battery charger stops working.
Contact service dept. or
change product.
19
Internal logic fault.
Battery charger stops working.
Contact service dept. or
change product.
242
Error when reading
internal memory on
microcontroller.
Battery charger stops working.
Contact service dept. or
change product.
252
Short‑circuit in bat‑
tery charger output.
Battery charger stops working.
Turn off battery charger
and resolve short‑circuit at
output. If problem persists,
contact service dept. or
change product.
246
Stage 1 ended by
timeout without
reaching control
voltage.
Battery charger stops working.
Make sure battery capacity
is compatible or check that
battery is compliant with
battery charger. If battery
is correct and problem per‑
sists, contact service dept.
241
Problem in CANBUS
communication with
other systems in the
network.
The way this is managed may
change based on different
firmware releases.
Check correct operation of