SECTION 6 - JLG CONTROL SYSTEM
3121253
– JLG Lift –
6-27
99133
99
POWER MODULE FAILURE - HWFS CODE 15
Hardware failsafe tests failed because the hardware failsafe the
contactor drive failsafe did not trip within the allowed test time
99134
99
POWER MODULE FAILURE - HWFS CODE 16
Hardware failsafe tests failed because the hardware failsafe the
contactor drive failsafe tripped tooslowly
99135
99
POWER MODULE FAILURE - HWFS CODE 17
Hardware failsafe tests failed because the hardware failsafe the
drive contactor failsafe tripped too quickly
99136
99
POWER MODULE FAILURE - HWFS TEST STALLED
Hardware failsafe tests did not complete, but no reason can be
determined
99137
99
POWER MODULE FAILURE - LINE CONTACTOR DRIVER
The line contactor energized when the footswitch was CLOSED
before it was ON, this maybe due to a failed driver within the
power module, or a power wiring error
99138
99
POWER MODULE FAILURE - TEMPERATURE SENSOR
The temperature sensor measurement is invalid, this maybe due
to a disconnected wire within the power module.
99139
99
POWER MODULE FAILURE - CONTACTOR CODE 1
A contactor remained energized when turned OFF
99140
99
TILT MODULE FAILURE - INTERNAL ERROR
Startup test detected faulty tilt sensors, or voltages on the tilt sen-
sor are bad (could be caused if positilt is mounted upside down or
vertical
99141
99
GROUND MODULE - OBSOLETE ON THIS VEHICLE
The power module determined the hardware version of the
Ground module was incompatible with the current software
99142
99
48V PROTECTION TRIPPED
The power module is not receiving acknowledgements from the
platform module or ground module to transmitted data, and the
protection circuit which supplies the platform and ground mod-
ules has tripped. This maybe due to wiring problems at the plat-
form or groundmodule.
Table 6-4. E300 Diagnostic Fault Codes
DTC
Flash
Code
Fault Message
Description