beautypg.com

JLG E300 Service Manual User Manual

Page 195

background image

SECTION 6 - JLG CONTROL SYSTEM

3121253

– JLG Lift –

6-27

99133

99

POWER MODULE FAILURE - HWFS CODE 15

Hardware failsafe tests failed because the hardware failsafe the
contactor drive failsafe did not trip within the allowed test time

99134

99

POWER MODULE FAILURE - HWFS CODE 16

Hardware failsafe tests failed because the hardware failsafe the
contactor drive failsafe tripped tooslowly

99135

99

POWER MODULE FAILURE - HWFS CODE 17

Hardware failsafe tests failed because the hardware failsafe the
drive contactor failsafe tripped too quickly

99136

99

POWER MODULE FAILURE - HWFS TEST STALLED

Hardware failsafe tests did not complete, but no reason can be
determined

99137

99

POWER MODULE FAILURE - LINE CONTACTOR DRIVER

The line contactor energized when the footswitch was CLOSED
before it was ON, this maybe due to a failed driver within the
power module, or a power wiring error

99138

99

POWER MODULE FAILURE - TEMPERATURE SENSOR

The temperature sensor measurement is invalid, this maybe due
to a disconnected wire within the power module.

99139

99

POWER MODULE FAILURE - CONTACTOR CODE 1

A contactor remained energized when turned OFF

99140

99

TILT MODULE FAILURE - INTERNAL ERROR

Startup test detected faulty tilt sensors, or voltages on the tilt sen-
sor are bad (could be caused if positilt is mounted upside down or
vertical

99141

99

GROUND MODULE - OBSOLETE ON THIS VEHICLE

The power module determined the hardware version of the
Ground module was incompatible with the current software

99142

99

48V PROTECTION TRIPPED

The power module is not receiving acknowledgements from the
platform module or ground module to transmitted data, and the
protection circuit which supplies the platform and ground mod-
ules has tripped. This maybe due to wiring problems at the plat-
form or groundmodule.

Table 6-4. E300 Diagnostic Fault Codes

DTC

Flash

Code

Fault Message

Description