beautypg.com

JLG E300 Service Manual User Manual

Page 187

background image

SECTION 6 - JLG CONTROL SYSTEM

3121253

– JLG Lift –

6-19

7
(Platform Alarm)

0

1

No - Sounds continuously when above elevation and tilted only.

Fault Code - Sounds continuously when above elevation and tilted, and in conjunction
with fault code flashes. Option

0

8
(Load)

0

1

2

3

NO - No Load Cell Installed

WARN ONLY - Warn if overload is detected

CUTOUT PLT - Cuts out Platform functions if overload is detected

CUTOUT ALL - Cuts out ALL functions if overload is detected

0

9
(Level inhibit)

0

1

NO

ELEV - Platform level can not operated when boom is raised above transport position

0

10
(ALARM dB)

Adjusts output of alarm
Range 90 - 107 dB

90

1001115577-2

Table 6-2. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default

Number