9. Emergency Operation

Emergency Operation Procedures

The fol low ing pro ce dures are emer gency pro ce -
dures only. DO NOT use them for nor mal op er a -
tion. Their pur

pose is to get the plat

form and

op er a tor safely to ground when the MHP16/47 will
not start or some other prob lem keeps the plat form
from low er ing in the nor mal way.

Operation From Platform Control Box

Switch set tings listed in the three steps be low must
ex ist at the ground be fore emer gency op er a tion
pro ce dures will work at the plat form con trol box:

Figure 9.1 - Lower Control Box

1. The Master Key Switch  must be ON (see

Figure 9.1).

2. The Emergency Stop switch € must be

(ON) (see Figure 9.1).

3. The Platform/Ground Selector switch 

(see Figure 9.1) must be set to PLATFORM.

Figure 9.2 - Upper Control Box

4. Set the Emergency Stop switch ‚ to ON

(see Figure 9.2).

5. Set the Anti-Restart switch ƒ (see Figure

9.2) to ON.

Figure 9.3

6. Step on the platform foot switch „ (see

Figure 9.3).

Figure 9.4

7. Hold the Emergency Lower switch … (see

Figure 9.4) down and the platform will begin
lowering.

NOTE:

To slew when using emergency lowering operate
the slew switch
† in the direction required.