Operation Considerations

To use this chap ter, first de cide whether you will be
start

ing and op

er

at

ing the MHP16/47 from the

ground con trol box or the plat form con trol box.

Be gin at the sec tion en ti tled "Starting From Ground
Con

trol Box", if you in

tend to start and run the

MHP16/47 from the ground sta tion.

Be gin at the sec tion en ti tled "Starting From Plat -
form Con trol Box", if you in tend to start and run the
MHP16/47 from the plat form.

Starting From Ground Control Box

Be fore you be gin to op er ate the MHP16/47 from
the ground con trol box, a qual i fied op er a tor must
per form the "Daily In spec tion and Main te nance" as
de scribed in chap ter 7, of this man ual.

To start the en gine from the ground con trol box do
the fol low ing:

1. Set the Emergency Stop switch  to ON

(see Figure 8.3).

Figure 8.3

2. Set the Platform/Ground Selector switch €

to GROUND (see Figure 8.3).

3. Insert the key  (see Figure 8.3) into the

Master Key Switch and turn the key on.

4. If the engine is at ambient temperature

(cold), hold the Choke / Cold Start Switch

‚ (see Figure 8.3) up throughout the next
step.

5. Turn the key to Start and hold it there un til

the en gine starts or for a max i mum time of 6
sec onds. When the en gine starts re lease the
key  and the choke switch ‚, if you used it
(see Figure 8.3).

If the engine does not start in 6 seconds turn
the key off and release the choke. Wait 60
seconds before trying to restart the engine
again. Continual cranking of the starter
motor will only result in its damage.

The en gine should now be run ning, and the
MHP16/47 is ready to be gin work.

Stabiliser Operation

En sure that the boom/sta bi liser switch (item ƒ on
the ground con trol box, see Fig ure 8.3) is set to
stabliiser.

Ac ti vate the sta bi lis ers with the valve le vers en sur -
ing that the front sta bi lis ers are low ered first to pre -
vent dam age to the jockey wheel.

Ac ti vate the rear sta bi lis ers and level the ma chine
us ing the level bub ble ad ja cent to the con trol le -
vers.

Ensure all four foot plates are in full contact
with the ground and that they are clear of
manhole covers, drains and unstable
ground etc.