Daily inspection and maintenance, Daily inspection and maintenance table 7-1, Daily inspection and maintenance table, 7-1 – Snorkel MHP17 User Manual
Page 37: Operators daily inspection, 7-1, Inspection and maintenance table, 7-1, Qualified, 7-1, 8-2, Daily inspection and maintenance table -1, Danger

7. Daily Inspection and Maintenance
At the start of each work day (or 8 hour shift), an
MHP16/47 qual i fied op er a tor must per form the
Daily In spec tion and Main te nance as listed in the
ta ble be low.
The pur pose of the Daily In spec tion and Main te -
nance is to keep the MHP16/47 in proper work ing
con di tion and to de tect signs of mal func tion at the
ear li est pos si ble time.
The MHP16/47 should be in the STOWED
POSITION and the Mas ter Key Switch set to OFF
be fore you be gin this in spec tion.
De fec tive parts and/or equip ment mal func tions
jeop ar dize the safety of the op er a tor and other per -
son nel, and can cause dam age to the ma chine.
DO NOT operate an MHP16/47 that is known
to be damaged or malfunctioning.
R e p a i r a l l e q u i p m e n t d a m a g e o r
malfunctions, before placing the MHP16/47
into service.
MHP16/47 – 11544A
page 7 - 1
Item
Service Required
Engine fuel level
Look to see that the fuel tank is full
Fuel tank cap
Check to see that the cap is tight
Engine oil level
Check oil level (between dipstick lines)
Fuel leaks
Visually inspect (hoses and connections)
Engine coolant
Check that grills are not blocked
Wiring harnesses
Visually inspect (installation, condition)
Battery terminals
Visually inspect (no corrosion)
Battery fluid level
Check fluid level (1/4" or 6 mm below filler neck)
Hydraulic oil level
Visually inspect level (between lines on gauge)
Hydraulic oil leaks
Visually inspect (hoses, tubes)
Tires and wheels
Visually inspect (condition)
Bolts and fasteners
Visually inspect (condition)
Structural damage and welds
Visually inspect (weld cracks, dents)
Lanyard anchor points
Visually inspect (condition)
Platform gravity gate
Check condition and operation
Platform guardrails
Visually inspect (condition)
Flashing light (option)
Visually inspect (operation)
Ground control switches
Actuate and inspect for proper operation
Level sensor (option)
Check operation
Emergency lower
Check operation (causes correct motion)
Platform control box switches
Actuate and inspect for proper operation
RCD/ELCB AC outlet (option)
Check operation
Platform work lights (option)
Check operation
Placards and decals
Visually inspect (installation, condition)
■ Daily Inspection and Maintenance Table
DANGER