16. TROUBLESHOOTING

104

Cause Check

Remedy

Page

Needle plate position





Adjust the forward/back position of the needle plate
so that the needle is in the center of the needle
hole.

-

Needle plate

Burr on the screw hole
edge (in event of uneven
material feeding)




Polish with buff.

-

Upper thread
trimmer assembly

Needle strikes upper
thread trimmer

Refer to “16-16. Needle strikes upper thread
trimmer”.

102, 103

Cutter Clearance

between

needle bar and cutter











Install the cutter so that the clearance between the
needle bar and the cutter is 0.3 mm.
* The cutter release section of the needle bar

should be at a right angle to the cutter.

74

ውዒ-ውዔ. Imperfect cutter function (imperfect material cutting)

Cause Check

Remedy

Page

Installation position of
cutter

Install the cutter so that its edge is aligned with the
top of the needle plate.

74

Cutter blade

࡮If blade is worn or chipped, sharpen it or replace it.

࡮Replace with the special needle plate (optional).

4

Cutter

Damage to cutter
mechanism parts
Loose screws

࡮Replace any parts that are damaged.
࡮Tighten any loose screws.

-

Cutter solenoid

Check for a disconnected
cord.

Connect the cords.

-

Cutter power

Memory switches

If the material is heavy and difficult to cut, use
memory switch No. 00 to increase the cutting force
of the cutter.

79

4015Q

Bisect

4014Q

4016Q

0.3 mm

(Needle plate cross section)

Check the chamfered side