FAA Approved Installation Manual for the
Report No 908
EDM-900 and EDM-930
Page 7 of 50 Rev J
Primary Engine Data Management System Date 5-24-14
EDM-900 TFT Flat panel display
Portrait Mode
EDM-900 TFT Flat
panel display
Landscape Mode
EDM-900 system mounts in a 3.125 inch diameter instrument panel hole in either a portrait or landscape position
depending on panel hole location. By holding the Step button ( first on left) for approx. 10 seconds and arrow will
appear on the display showing which way the rotation will use as up. Use the LF (Second from left) button to index
the rotation arrow. When the proper position is achieved, tap the step button Tap STEP to save the new rotation.
At this point properly the rotation will be saved and the unit will reboot to the new rotation. The rotation will not
occur if the engine is running.
Remote Alert Light
With the placard
“Engine”