FAA Approved Installation Manual for the

Report No 908

EDM-900 and EDM-930

Page 18 of 50 Rev J

Primary Engine Data Management System Date 5-24-14

- BATT +

Master switch

Starter

Starter solenoid

Master switch

contactor

Bus

F G

B

external shunt

Ammeter Configuration

Alternator

+

20.2

Load Meter Configuration

Alternatively the shunt can be installed between the alternator output and the main bus in which case it will be the
load meter configuration showing alternator load (positive only). Be sure that the negative side of the shunt is
connected to the main bus in the load meter configuration. There is no alarm.

21. General Fuel Flow Transducer Installation

Use the J4 connector harness 700708 labeled FFSIG (white), FFPWR (red), and FFGND (black). If no previous fuel
flow transducer is installed, install transducer per APPENDIX-A Report 503 FUEL FLOW TRANSDUCER
INSTALLATION.

- BATT +

Master switch

Starter

Starter solenoid

Master switch

contactor

Bus

F G

B

external shunt

Load Meter Configuration