FAA Approved Installation Manual for the
Report No 908
EDM-900 and EDM-930
Page 26 of 50 Rev J
Primary Engine Data Management System Date 5-24-14
7. Tap
TANK to select the next active tank and repeat previous step. Continue until all tanks ‘points’ have
been set.
8.
Tap TABLE. You see ‘Fuel Table Data’ ( White at top of screen) with a table. You may change any of the
fuel levels in the left column except for empty. You will enter the readings taken previously on paper into
the right column.
9. Tap/hold
STEP to select the cell you want to edit. Tap EDIT to change the value. Tap or hold Modify to
change digit. Tap digit to change another part of the number.
10. Tap SAVE to record it. Follow the on-screen menus to edit the value. Repeat previous step until all tanks
data have been entered.
11. You see ‘Save fuel tank data?’. Answer SAVE to store all final data values or CANCEL to return to table
editing. To complete the process, tap SAVE a second time.
23. Fuel Flow Totalizer, Refuel Question
The fuel flow totalizer can be set to a different value than the fuel level tank size. To reprogram the “Refuel
setting for Main (total) and Auxiliary (total), enter the “Factory Program Mode” by holding buttons 1 and 2 in for a
few seconds until the display reads “Program”. Keep tapping next until you see “END”. At this point hold in button