FAA Approved Installation Manual for the
Report No 908
EDM-900 and EDM-930
Page 25 of 50 Rev J
Primary Engine Data Management System Date 5-24-14
3. Tap USER when you see ‘Do you want to restore user table?’
(Note: tapping FACTORY
causes the fuel table stored on the Key Card to over-write any previous user entries in the fuel table. Use
FACTORY if you want to start from the original factory default).
4. Tap
POINTS when you see ‘Do you want to edit the table?’.
5. You see ‘Points in LEFT’, the current calibration points for the LEFT tank.
6. Tap/hold
VALUE to change to the desired number of calibration points for this tank (2 to 5). Each
Tank can have a different set of calibration points. So 5 points for Main and 2 points for Aux.