C. replace in-line fuel strainer, 500 hour intervals), Unlock and open the right rear engine access door – SkyTrak 6042 Operation Manual User Manual
Page 129: Close and lock the right rear engine access door, Figure 80, General maintenance

General Maintenance
127
Model 6042
Origin 5/02
C. Replace In-line Fuel Strainer
(500 Hour Intervals)
1. Unlock and open the right rear
engine access door.
2. The in-line fuel strainer (Figure 80, 1) is located down line from the
engines lift pump (2). Loosen the two hose clamps (3) that secure
the strainer in place.
3. Remove the old in-line fuel strainer and dispose of properly.
4. Install the new in-line fuel strainer (Figure 80, 1) with arrow pointing
toward the lift pump (2).
5. Assemble the hoses to the in-line fuel strainer and tighten the hose
clamps.
6. Remove air from the fuel system (see “Bleeding Fuel System” on
page 128).
7. Close and lock the right rear engine access door.
Figure 80
500
OT1150
OH2200
1
2