beautypg.com

Warning, Turbo, Intake manifold press – Defi Link Meter User Manual

Page 28

background image

81

1. The rubber hose attached to the sensor should be as short as possible.

Attach it with bolts (M6) in the engine compartment in an area where it
will not be subject to excess heat or vibration.

2. Access to the air pressure intake may be obtained between the surge

tank and the fuel regulator

(A)Detach the vacuum hose from the surge tank side that has loss

pressure oscillations, and connect it to the three way connector at
point(b)or(a).

(B)In order to connect the surge tank with three way connector, cut the

required length of hose from the included rubber hose.

(C)Use the remaining rubber hose to connect the sensor to the three way

connector.

●The length of the included rubber hose is 0.5m (1 3/5ft.) Please adjust appropriately.
●The sensor must be installed being faced to the connector to the rubber hose down.
●For vehicles which have a solenoid valve between the surge tank and the fuel

pressure regulator, place a three-way joint before the solenoid.

CONFIRMATION

● HOW TO ATTACH SENSORS(for installation personnel)

TURBO

Surge tank

Fuel regulator

Three-way

joint

Rubber hose

Sensor

*Be sure to be installed being

faced the air hole down.

(a)

(b)

(c)

Attach with
clamps.

(commercially

available)

Sensor wire

→To Control Unit Ⅱ

INTAKE MANIFOLD PRESS.

●To avoid disconnection of rubber hoses during pipe installation, use tie-wraps to

secure to adjacent hoses in the engine compartment.

WARNING

This manual is related to the following products: