11-4

BE-0901E-AC-PC• BE-1201B-AC-PC

Chapter 11 Error code list

Code

Error

Measures

E-CB

Spindle rotation speed error

Press the

to cancel the error and press the

If the

same error occurs again, there is a possibility that the spindle is
overloaded..

E-CD

Speed command can not be received.

Turn the power off and on once. If the same error occurs again,
the main PCB is faulty.

E-E3

Cooling fan motor stop.

Turn off the power and check the fan harness. Turn on the
power again. If the same error occurs again, the fan or the main
PCB is faulty.

E-E5

Over-run error during interfacing to main PCB
CPU

E-E6

Framing error during interfacing to main PCB
CPU

E-E7

Parity error during interfacing to main PCB
CPU

E-E8

Receiving time up error during interfacing to
main PCB CPU

E-E9

Send/Receive inconsistent error during
interfacing to main PCB CPU

E-EA

ACK code receiving error during interfacing to
main PCB CPU

E-EB

Send/Receive ID code error during interfacing
to main PCB CPU

E-EC

Send data checksum error during interfacing to
main PCB CPU

E-ED

Data empty error during interfacing to main
PCB CPU

E-EE

Receiving error on interface

E-F1

Send time up error

E-F2

Request-to-waiting time up error

E-F3

Request-to-recive time up error

E-F4

Receive command error

E-F5

NACK code receiving error

E-F6

Data requested for needle position can not be
returned.

E-F7

It is not receive command for the request one.

E-F8

PRE code error

E-F9

No applicable command

E-FA

Interface receive data sum check error

E-FB

Send time up error

E-FF

No status is returned from main shaft CPU.

This is not usually displayed.