8-8

BE-0901E-AC-PC• BE-1201B-AC-PC

Chapter 8 Creating Production Report

Display Example of Output Information

Displays the production information that are collected during the specified period.

Display

Contents

Total electricity supply time

Total time when the machine was energized within the specified
period(**)

Total embroidering time

Total time when the machine embroidered within the specified
period

Total actual embroidering time

Total actual time when the machine embroidered within the
specified period

Excluded time

Total time of intermission and maintenance for the number of days
in the specified period

Electricity supply efficiency

Electricity supply efficiency by calculating below:
(Total electricity supply time - excluded time) / total electricity
supply time

Embroidering efficiency period

Ratio of the actual embroidering time to the total embroidering time
Total actual embroidering time / total embroidering time

Number

The pattern embroidered during the specified period is numbered.

Pattern name

Name of the pattern

No. of stitches in pattern

Number of stitches in the pattern

Total stitches (*)

Total number of stitches by repeating embroidering
No. of stitches in pattern X No. of times embroidered

No. of colors in pattern (*)

Number of colors in the pattern

No. of times embroidered (*)

Number of embroidering repeated

No. of workpieces embroidered (*)

Number of finished sheets by one embroidering cycle

Total no. of heads which are stopped

Total number of the heads at rest for one embroidering cycle

Embroidering time (*)

Time from embroidering start to the end for the pattern

Actual embroidering time (*)

Embroidering time from which the time for interruption, stop due to
thread breakage, and stop due to error is excluded

Average embroidering speed

Average embroidering speed in the actual embroidering time (the
number of stitches per minute)
Total stitches/actual embroidering time

Efficiency 1 (*)

Ratio of the actual embroidering time to the embroidering time for
the pattern with time for interruption excluded
Actual embroidering time/(embroidering time-time for interruption)

Efficiency 2 (*)

Ratio of the actual embroidering time to the embroidering time
Actual embroidering time / embroidering time

Time stopped (*)

Total of stop time during embroidering

Reason for stoppage (*)

Reasons for stoppage are indicated. Refer to the next page.