Saf-te test – Toshiba Magnia Z500 User Manual
Page 91
HW Diagnostics
Items of HW Diagnostics
89
For the definition of ERROR NAME and STS, refer to the table
[SCSI HDD TEST (HDD)] in [Chapter 4 - 06.SCSI HDD TEST].
For the definition of Details, refer to following description:
*Definition of CD-ROM TEST Details Information
(DETAILS=XXXXXXXXXXXXXX)
AAA BB CC DD EE FF GG
AAA
:
Case of IDE CD-ROM device
PrM
(Primary, Master)
PrS
(Primary, Slave)
ScM
(Secondary, Master)
ScS
(Secondary, Slave)
BB
:
Sense data (0 byte)
CC
:
Sense data (1 byte)
DD
:
Sense data (2 byte) [Sense Key]
EE
:
Sense data (12 byte)[Expansion Sense code]
FF
:
Sense data (13 byte)[Expansion Sense code]
GG
:
Sense data (14 byte)
NOTE: On the MAGNIA Z500, the CD-ROM test tests only
one IDE CD-ROM drive.
The CD-ROM test searches for CD-ROM device, according
to the order as shown below, and tests the first found CD-
ROM device only.
IDE (PrM, PrS, ScM, ScS), SCSI (ID0, ID1,…)
[11. SAF-TE TEST]
To check the SAF-TE function and the status LED of the hard disk
drives (Even if the SCSI HDD does not exist on your computer,
this test can be executed, however nothing is tested.).
[01. SAF-TE test]
It detects SAF-TE controller and checks the operation by
flashing the LED for each hard disk drive.