beautypg.com

Saf-te test – Toshiba Magnia Z500 User Manual

Page 91

background image

HW Diagnostics

Items of HW Diagnostics

89

For the definition of ERROR NAME and STS, refer to the table
[SCSI HDD TEST (HDD)] in [Chapter 4 - 06.SCSI HDD TEST].

For the definition of Details, refer to following description:

*Definition of CD-ROM TEST Details Information
(DETAILS=XXXXXXXXXXXXXX)

AAA BB CC DD EE FF GG

AAA

:

Case of IDE CD-ROM device
PrM

(Primary, Master)

PrS

(Primary, Slave)

ScM

(Secondary, Master)

ScS

(Secondary, Slave)

BB

:

Sense data (0 byte)

CC

:

Sense data (1 byte)

DD

:

Sense data (2 byte) [Sense Key]

EE

:

Sense data (12 byte)[Expansion Sense code]

FF

:

Sense data (13 byte)[Expansion Sense code]

GG

:

Sense data (14 byte)

NOTE: On the MAGNIA Z500, the CD-ROM test tests only
one IDE CD-ROM drive.
The CD-ROM test searches for CD-ROM device, according
to the order as shown below, and tests the first found CD-
ROM device only.

IDE (PrM, PrS, ScM, ScS), SCSI (ID0, ID1,…)

[11. SAF-TE TEST]

To check the SAF-TE function and the status LED of the hard disk
drives (Even if the SCSI HDD does not exist on your computer,
this test can be executed, however nothing is tested.).

[01. SAF-TE test]

It detects SAF-TE controller and checks the operation by
flashing the LED for each hard disk drive.