7.1
[System Settings]
7
7
Place 10 or more sheets of blank paper on top of the test pattern to prevent it from becoming transpar-
ent.
8
Close the ADF or Original Cover.
9
Press the Start key.
The test pattern is scanned.
10
Repeat steps 2 through 9 two more times.
[Initialize Adjustment Value]
Clear the correction values of both [Maximum Density Adjustment] and [Gradation Adjustment], and return
them to the factory default value (0).
1
Press the Utility/Counter key ö [Administrator Settings] ö [System Settings] ö [Expert Adjustment]
ö [Gradation Adjustment].
2
Press [Initialization].
3
Select [Initialize], and press the Start key.
This starts resetting the correction value.
7.1.8
[List/Counter]
Configure the job settings list print settings and paper count settings for this machine.
%
Press the Utility/Counter key ö [Administrator Settings] ö [System Settings] ö [List/Counter].
Settings
[Management List]
[Job Settings List]
Configure paper tray settings for printing the job
settings list and specify a print side.