6 particular adjustment, Particular adjustment -25 – Konica Minolta bizhub PRESS C1085 User Manual
Page 75
bizhub PRESS C1100/C1085
6-25
6.2
Image Quality Adjustment
6
Tips
-
Exact Color and G7 Calibration, which are high-level calibration functions, are set so that either one of
them is available. If you want to change the function, contact your service representative.
6.2.6
Particular adjustment
If a particular adjustment is required, for example, before printing out an image with a higher level of quality
or when the expected chromogenic effect has not been obtained as expected, adjust the following items:
d
Reference
For details about the adjustment procedure, refer to the [HTML User's Guide].
NOTICE
Precaution on using [Color Density Control]
To use [Each Paper Type Color Adj.] in [Color Density Control], carry out [Each Paper Type Color Adj.] before
starting this procedure, then configure a tray setting.
For details, refer to the [HTML User's Guide].
Adjustment
order
Menu item
Description
Tips
1
Gamma Auto-
matic Adj.
Adjusts the curve of the output density against
the input density.
This affects the brightness and contrast.
On the [MACHINE] screen, select [ADJUST-
MENT] - [Execute Adjust Operation] - [Gamma
Automatic Adj.] to execute processing.
[HTML User's
Guide]
2
Maximum Den-
sity Adjustment
Changes the maximum density adjustment value
when the measurement density that was ob-
tained after calibration does not match the refer-
ence adjustment value.
[Administrator Setting] - [System Setting] - [Ex-
pert Adjustment] - [Process Adjustment] - [Maxi-
mum Density Adjustment]
[HTML User's
Guide]
3
Color Density
Control
Executes automatic calibration.
On the [MACHINE] screen, select [ADJUST-
MENT] - [Color Density Control] - [Basic Setting]
or [Color Density Manual Control] to carry out the
adjustment.
4
Printer control-
ler calibration
Executes manual calibration.
Use Fiery Command WorkStation.