Konica Minolta bizhub PRESS C1085 User Manual
Page 72
Image Quality Adjustment
6
6-22
bizhub PRESS C1100/C1085
6.2
5
Click [Continue].
A chart is printed out in a matter of time after
this machine started running.
6
Click [OK].
7
Securely place EFI Spectrometer ES-1000 in
the calibration cradle, then click [Continue].
8
Load the measurement page on the measurement guide plate.
9
Follow the instructions on the measurement
screen to measure color strips in sequence.
% Place approximately 10 sheets of plain pa-
per beneath the measurement page or use a
backer board, before starting measurement.
% Hold down the measurement button of EFI
Spectrometer ES-1000. After you hear a
beep, slide it while holding down the meas-
urement button.
Slide EFI Spectrometer ES-1000 to the end
of strip, then release the measurement but-
ton.
% For details about how to use EFI Spectrom-
eter ES-1000, refer to the manual supplied
with this machine.