Table 5. eeprom boot configuration commands, Shown in table 5, Cs5376a – Cirrus Logic CS5376A User Manual
Page 29: Sample command

CS5376A
DS612F4
29
Sample Command:
Write IIR1 coefficients 0x84BC9D, 0x7DA1B1,
0x825E4F, and IIR2 coefficients 0x83694F,
0x3CAD5F, 0x3E5104, 0x835DF8, 0x3E5104.
03
84 BC 9D 7D A1 B1 82 5E 4F 83 69 4F
3C AD 5F 3E 51 04 83 5D F8 3E 51 04
Write ROM Coefficients - 0x04
This EEPROM command selects the on-chip coef-
ficients for the FIR1, FIR2, IIR 1st order, and IIR
2nd order filters for use by the digital filter. One
data word is required to select which internal coef-
ficient sets to use. See “Filter Coefficient Selec-
tion” on page 41 for information about selecting
on-chip FIR and IIR coefficient sets.
Sample Command:
Select IIR1 and IIR2 3 Hz @ 500 SPS low-cut co-
efficients, with FIR1 and FIR2 linear phase high-
cut coefficients. Data word 0x002200.
04 00 22 00
Write TBS Data - 0x05
This EEPROM command writes a custom data set
for the test bit stream (TBS) generator. This com-
mand, along with the ability to program the test bit
stream generator interpolation and clock rate, can
create custom frequency test signals.
The first data word sets the number of TBS data to
be written and the remaining data words are the
TBS data values. See “Test Bit Stream Generator”
on page 64 for information about using custom test
bit stream data sets.
Table 5. EEPROM Boot Configuration Commands
(DATA) indicates multiple words of this type are to be written.
Name
CMD
8-bit
DATA
24-bit
Description
NOP
00
-
No Operation
WRITE DF REGISTER
01
REG
DATA
Write Digital Filter Register
WRITE FIR COEFFICIENTS
02
NUM FIR1
NUM FIR2
(FIR COEF)
Write Custom FIR Coefficients
WRITE IIR COEFFICIENTS
03
a11
b10
b11
a21
a22
b20
b21
b22
Write Custom IIR Coefficients
WRITE ROM COEFFICIENTS
04
COEF SEL
Use On-Chip Coefficients
WRITE TBS DATA
05
NUM TBS
(TBS DATA)
Write Custom Test Bit Stream Data
WRITE ROM TBS
06
-
Use On-Chip TBS Data
FILTER START
07
-
Start Digital Filter Operation