See "configuration 59, Configuration 58 (config58) – address – Cirrus Logic CS1631 User Manual
Page 48

CS1630/31
48
DS954F3
6.39 Configuration 58 (Config58)
–
Address 90
6.40 Configuration 59 (Config59)
–
Address 91
7
6
5
4
3
2
1
0
SHUTDWN3
SHUTDWN2
SHUTDWN1
SHUTDWN0
LOW_SAT2
LOW_SAT1
LOW_SAT0
DIM_TEMP
Number
Name
Description
[7:4]
SHUTDWN[3:0]
Configures the 8-bit code value corresponding to temperature threshold
Temp
Shutdown
. If the temperature exceeds this threshold, the device enters an
external overtemperature state and shuts down.
The wakeup temperature code is configured as an offset from the eOTP tem-
perature code and the shutdown temperature code is configured as an offset
from the wakeup temperature code; Temp
eOTP
< Temp
Wakeup
< Temp
Shutdown
[3:1]
LOW_SAT[2:0]
Sets the lower saturation limit for the 8-bit temperature code provided to the
color system from the fast low pass filter before it is used for polynomial com-
putations.The lower saturation limit is given by:
[0]
DIM_TEMP
Configures the external overtemperature protection (eOTP) dim with tempera-
ture feature, which decreases the second stage dim level once the tempera-
ture measured using the external NTC connected to pin eOTP exceeds the
temperature threshold set using eOTP[4:0], Temp
eOTP
(see “Configuration 59
(Config59) – Address 91” on page 48).
0 = Disable
1 = Enable
7
6
5
4
3
2
1
0
eOTP4
eOTP3
eOTP2
eOTP1
eOTP0
HI_SAT2
HI_SAT1
HI_SAT0
Number
Name
Description
[7:3]
eOTP[4:0]
Configures 8-bit code value CODE
TEMPeOTP
corresponding to the tempera-
ture Temp
eOTP
set point at which the eOTP dim with temperature feature is
enabled.
[2:0]
HI_SAT[2:0]
Sets the higher saturation limit for the 8-bit temperature code provided to the
color system before it is used for polynomial computations.
000 = CODE
TEMPShutdown
001 = 100
010 = 120
011 = 140
100 = 160
101 = 180
110 = 200
111 = 220
CODE
TEMPShutdown
CODE
TEMPWakeup
SHUTDWN
+
[3:0] 4
=
LOW_SAT[2:0]
1
+
5
CODE
TEMPeOTP
80
eOTP
+
[4:0] 4
=