29 configuration 47 (config47) – address 79 – Cirrus Logic CS1631 User Manual
Page 41

CS1630/31
DS954F3
41
6.29 Configuration 47 (Config47)
–
Address 79
7
6
5
4
3
2
1
0
OCP
OLP
OVP
BOP
COP
LLP
EEOTP
IOTP
Number
Name
Description
[7]
OCP
Configures second stage primary side overcurrent protection.
0 = Enable
1 = Disable
[6]
OLP
Configures second stage primary side open loop protection (R
Sense
Short Pro-
tection).
0 = Enable
1 = Disable
[5]
OVP
Configures second stage secondary side overvoltage protection (Output Open
Circuit Protection).
0 = Enable
1 = Disable
[4]
BOP
Configures boost overvoltage protection.
0 = Enable
1 = Disable
[3]
COP
Configures clamp overpower protection.
0 = Enable
1 = Disable
[2]
LLP
Configures line link protection.
0 = Enable
1 = Disable
[1]
EEOTP
Configures external overtemperature protection.
0 = Enable
1 = Disable
[0]
IOTP
Configures internal overtemperature protection.
0 = Enable