6.17 Configuration 12 (Config12)
–
Address 44
6.18 PU Coefficient (PID)
–
Address 45
PID sets the maximum coefficient for the second stage PU integrator. The register value is an unsigned integer
in the range of 0
value255.
6.19 Maximum Switching Frequency (TTFREQ)
–
Address 46
TTFREQ sets the minimum switching period (maximum switching frequency) for the second stage TT (see
"Maximum TT (TTMAX) – Address 38" on page 33). The register value is an unsigned integer in the range of
0
value255. The minimum TTFREQ switching period is determined by:
The switching period for TT can be configured from 0ns to 51
s.
7
6
5
4
3
2
1
0
TIMEOUT1
TIMEOUT0
S2CONFIG
DITATT1
DITATT0
-
-
-
Number
Name
Description
[7:6]
TIMEOUT[1:0]
Sets the T2 time-out limit to ensure a minimum switching frequency for each
channel.
00 = 45ms
01 = 70.6ms
10 = 96.2ms
11 = 121.8ms
[5]
S2CONFIG
Configures second stage for flyback or buck/tapped buck.
0 = Enables second stage for buck/tapped buck topology
1 = Enables second stage for flyback topology
[4:3]
DITATT[1:0]
Configures the dither attenuation by right shifting the dither value on a selected
channel for dithering reduction. The nominal dither level (set using bits DIT-
LEVEL[1:0]) is attenuated by the amount configured by bits DITATT[1:0] on the
channel set using bit DITCHAN.
00 = No attenuation
01 = 50% attenuation
10 = 25% attenuation
11 = 12.5% attenuation
[2:0]
-
Reserved