beautypg.com

2 clearing an output, 3 clearing all the outputs, Clearing an output – Kramer Electronics VS-169TP User Manual

Page 29: Clearing all the outputs

background image

Operating the VS-169TP 16x9 CAT 5 Matrix Switcher

25

25

line of the selected signal blinks.

2. Press the appropriate IN button.

This input switches to all the outputs, and the MATRIX STATUS display

shows the selected input number.

To switch one input to all the outputs in the CONFIRM mode (the TAKE

button illuminates), do the following:
1. Press the ALL button.

The MATRIX STATUS display shows the three sets of blinking digits

(each representing the present input number for that respective output)

blinking simultaneously.

2. Press the appropriate IN button.

The current input settings blink alternately with the selected input number

digits, and the TAKE button blinks.

3. Press the TAKE button to confirm the action.

The selected input switches to all the outputs and the TAKE button

illuminates. The MATRIX STATUS display shows the identical digits

(representing the selected input number) for all outputs.

9.3.2 Clearing an Output

To clear an output (in the AT ONCE mode):
1. Press the appropriate OUT button.

The MATRIX STATUS display shows the two blinking digits,

representing the present input number for that specific output.

2. Press the OFF button.

The input is cleared and the MATRIX STATUS display does not show

any input number in its place.

9.3.3 Clearing all the Outputs

To clear all outputs (in the AT ONCE mode):
1. Press the ALL button.

The MATRIX STATUS display shows the three sets of digits

1

2. Press the OFF button.

The MATRIX STATUS display shows: RESET ALL OUTPUTS?

CONFIRM

and the TAKE button blinks.

blinking

simultaneously. In the breakaway mode, only the line of the selected

signal blinks

1 Each representing the present input number for that respective output