11 communication parameters, Communication parameters, Table 6: communication parameters – Kramer Electronics VP-885 User Manual
Page 44

KRAMER: SIMPLE CREATIVE TECHNOLOGY
Communication Parameters
40
11 Communication Parameters
lists the communication parameters as used in Kramer Electronics
products.
Table 6: Communication Parameters
RS-232
Protocol 2000
Protocol 3000 (Default)
Baud Rate:
9600
Baud Rate:
115,200
Data Bits:
8
Data Bits:
8
Stop Bits:
1
Stop Bits:
1
Parity:
None
Parity:
None
Command Format:
HEX
Command Format:
ASCII
Example (Output 1 to Input 1): 0x01, 0x81, 0x81, 0x81 Example (Output 1 to Input 1): #AV 1>1
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command:
0x38, 0x80, 0x83, 0x81
Command:
#P2000
Front Panel:
Press and hold Output 1 and
Output 3 simultaneously
Front Panel:
Press and hold Output 1 and
Output 2 simultaneously
Ethernet
Default Settings
Reset Settings
IP Address: 192.168.1.39
Subnet mask: 255.255.255.0
Gateway: 192.168.1.1
Power cycle the unit while holding in the Factory Reset button, located on
the rear panel of the unit.
TCP Port #: 5000
UDP Port #: 50000