10 the vp-460 rs-232 communication protocol, 1 the protocol 3000 common operation commands, The vp-460 rs-232 communication protocol – Kramer Electronics VP-460 User Manual
Page 49: The protocol 3000 common operation commands
![background image](/manuals/465000/49/background.png)
44
VP-460 - The VP-460 RS-232 Communication Protocol
10 The VP-460 RS-232 Communication Protocol
The Kramer Protocol lets you control the
VP-460 from any standard terminal
software (for example, the Windows
®
HyperTerminal Application).
This section describes the:
•
Protocol 3000 common commands, see
•
Audio video control commands (via protocol 3000), see
Section 10.1
•
The button functions (on the front panel and remote controller), see
Section 10.2
The protocol 3000 communications protocol uses a data rate of 115200 baud, with
no parity, 8 data bits, and 1 stop bit.
Section
10.1 The Protocol 3000 Common Operation Commands
Operation commands
Command
Syntax
Response
Lock front panel
LOCK-FP LOCK-MODE
LOCK-FP LOCK-MODE
RESULT
Get front panel
locking state
LOCK-FP?
LOCK-FP LOCK-MODE
Parameters Description:
LOCK-MODE
= Front panel locking state:
"0" or "off" to unlock front panel buttons.
"1" or "on" to lock front panel buttons.
Power state
POWER POWER-MODE
POWER POWER-MODE
RESULT
Get power state
POWER?
POWER POWER-MODE
Parameters Description:
POWER-MODE
= power state:
"0" or "off" to enter standby mode.
"1" or "on" to power up.
Restart device
RESET
RESET OK
Peripheral firmware
update execute*
UPGRADE
UPGRADE OK
Usually the firmware will upload to the device via a command such as LDFW
A device reset may be needed to complete the process
Video core Firmware UPGRADES