beautypg.com

Warnings, Safety – SawStop CNS175-AU User Manual

Page 9

background image

SawStop 10” Contractor Saw 7

5. The contractor saw in its standard configuration is intended for use on a 110-120V supply circuit that has an

outlet that looks like the one illustrated in Sketch A below.

A temporary adapter, which looks like the adapter illustrated in Sketch B and C, may be used to connect this plug

to a 2 pole receptacle as shown in Sketch B if a properly grounded outlet is not available. The temporary adapter

should be used only until a properly grounded outlet can be installed by a qualified electrician. This adapter

is not permitted in Canada. The green-colored rigid ear, lug, and the like, extending from the adapter must be

connected to a permanent ground such as a properly grounded outlet box.

6. A contractor saw that has been re-wired for 208-240V power

is intended for use on a circuit that has an outlet that looks like

the one illustrated in Sketch D. The saw has a grounding plug

that looks like the plug illustrated in Sketch D. Make sure the

saw is connected to an outlet having the same configuration

as the plug. No adapter is available or should be used with

this saw. If the saw must be reconnected for use on a different

type of electric circuit, the reconnection should be made by

qualified service personnel; and after reconnection, the saw

should comply with all local codes and ordinances.

Safety

Sketch D

grounding pin

grounding

pin

Sketch A

Sketch B

cover of grounded

outlet box

metal screw

cover of grounded

outlet box

Sketch C

grounding

means

adapter

adapter

!

WARNINGS

This manual is related to the following products: