5. Turn the impeller wear ring to size after you mount it on the impeller .
NOTICE:
The impeller and wear-ring clearance setting procedures must be followed. Improperly
setting the clearance or not following any of the proper procedures can result in sparks,
unexpected heat generation, and equipment damage.
All replacement impeller wear rings, except those that are hard-faced, are supplied 0.020
in. to 0.030 in. (0.508 mm to 0.762 mm) oversize. See the table Minimum running
clearances for final running clearances. Machine the impeller rings accordingly.
Spare hard-faced impeller wear rings are not supplied oversize but are supplied to pre-
established proper running clearances when both impeller and casing wear rings are
renewed.
When the impeller assembly is supplied as a spare part (impeller with wear rings), the wear
rings are machined to the required dimension.
Minimum running clearances
Impeller wear rings
Replace wear rings when the diametrical clearance exceeds the values shown in this table or when the
hydraulic performance has decreased to unacceptable levels:
Diameter of rotating member at clearance
Minimum diametrical clearance
in.
mm
in.
mm
<2.000
<50.00
0.010
0.25
2.000 to 2.4999
50.00 to 64.99
0.011
0.28
2.500 to 2.999
65.00 to 79.99
0.012
0.30
3.000 to 3.499
80.00 to 89.99
0.013
0.33
3.500 to 3.999
90.00 to 99.99
0.014
0.36
4.000 to 4.499
100.00 to 114.99
0.015
0.38
4.500 to 4.999
115.00 to 124.99
0.016
0.41
5.000 to 5.999
125.00 to 149.99
0.017
0.43
6.000 to 6.999
150.00 to 174.99
0.018
0.46
7.000 to 7.999
175.00 to 199.99
0.019
0.48
8.000 to 8.999
200.00 to 224.99
0.020
0.51
9.000 to 9.999
225.00 to 249.99
0.021
0.53
10.000 to 10.999
250.00 to 274.99
0.022
0.56
11.000 to 11.999
275.00 to 299.99
0.023
0.58
12.000 to 12.999
300.00 to 324.99
0.024
0.61
13.000 to 13.999
325.00 to 349.99
0.025
0.63
14.000 to 14.999
350.00 to 374.99
0.026
0.66
15.000 to 15.999
375.00 to 399.99
0.027
0.69
16.000 to 16.999
400.00 to 424.99
0.028
0.71
17.000 to 17.999
425.00 to 449.99
0.029
0.74
18.000 to 18.999
450.00 to 474.99
0.030
0.76
19.000 to 19.999
475.00 to 499.99
0.031
0.79
20.000 to 20.999
500.00 to 524.99
0.032
0.81
21.000 to 21.999
525.00 to 549.99
0.033
0.84
22.000 to 22.999
550.00 to 574.99
0.034
0.86
23.000 to 23.999
575.00 to 599.99
0.035
0.89
24.000 to 24.999
600.00 to 624.99
0.036
0.91
25.000 to 25.999
625.00 to 649.99
0.037
0.94
For diameters greater than 25.999 in. (649.99 mm), the minimum diametrical clearances shall
be 0.037 in. (0.94 mm) plus 0.001 inch for each additional inch of diameter or fraction thereof
(1 mm for each additional 1 mm).