Alignment checks, Permitted indicator values for alignment checks, Alignment measurement guidelines – Goulds Pumps 3610 - IOM User Manual
Page 23

Installation
Alignment checks
When to perform alignment checks
You must perform alignment checks under these circumstances:
• The process temperature changes.
• The piping changes.
• The pump has been serviced.
Types of alignment checks
Type of check
When it is used
Initial alignment (cold alignment)
Prior to operation when the pump and the driver are at ambient
check
temperature.
Final alignment (hot alignment)
After operation when the pump and the driver are at operating
check
temperature.
Initial alignment (cold alignment) checks
When
Why
Before you grout the baseplate
This ensures that alignment can be accomplished.
After you grout the baseplate
This ensures that no changes have occurred during the grouting
process.
After you connect the piping
This ensures that pipe strains have not altered the alignment.
Final alignment (hot alignment) checks
When
Why
After the first run
This ensures correct alignment when both the pump and the driver
are at operating temperature.
Periodically
This follows the plant operating procedures.
Permitted indicator values for alignment checks
NOTICE:
The specified permitted reading values are valid only at operating temperature. For cold
settings, other values are permitted. You must use the correct tolerances. Failure to do so can
result in misalignment and reduced pump reliability.
IMPORTANT
• For electric motors, the motor shaft initial (cold) parallel vertical alignment setting should
be 0.002 to 0.004 in. (0.05 to 0.10 mm) lower than the pump shaft.
• For other drivers such as turbines and engines, follow the driver manufacturer's
recommendations.
When dial indicators are used to check the final alignment, the pump and drive unit are
correctly aligned when these conditions are true:
• The total indicator runout is a maximum of 0.002 in. (0.05 mm) at operating temperature.
• The tolerance of the indicator is 0.0005 in./in. (0.0127 mm/mm) of indicator separation at
operating temperature.
Alignment measurement guidelines
Guideline
Explanation
Rotate the pump coupling half and the driver
This prevents incorrect measurement.
coupling half together so that the indicator rods
have contact with the same points on the driver
coupling half.
Move or shim only the driver in order to make
This prevents strain on the piping installations.
adjustments.
Installation, Operation, and Maintenance Manual