Bearings inspection – Goulds Pumps 3610 - IOM User Manual
Page 71
Maintenance
Shaft straightness check
NOTICE:Do not use shaft centers for the runout check as they may have been damaged during
the removal of the bearings or impeller.
Shaft surface check
Check the shaft surface for damage. Replace the shaft if it is damaged beyond reasonable
repair.
Rotor
Allowable runouts of the fully assembled rotor are listed in the Shaft and rotor runout
requirements table.
Table 1: Shaft and rotor runout requirements
Characteristic
Requirement
Flexibility factor, L
4
/D
2
>1.9x10
9
mm
(3.0x10
6
in.)
Allowable shaft runout, TIR
25 µm
(0.0010 in.)
Component fit to shaft
Clearance
Allowable rotor radial runout, TIR*
75 μm
(0.0030 in.)
*Total indicated runout of impeller hubs and sleeves
Figure 17: Fully assembled rotor
Bearings inspection
Condition of bearings
Do not reuse bearings. The condition of the bearings provides useful information on operating
conditions in the bearing frame.
Installation, Operation, and Maintenance Manual
69
- 3100 - IOM (52 pages)
- 3171 - IOM (60 pages)
- 3180-86 - IOM (158 pages)
- 3189 - IOM (32 pages)
- 3196 - IOM (148 pages)
- 3196 i-FRAME - IOM (152 pages)
- 3198 i-FRAME - IOM (126 pages)
- 3296 EZMAG - IOM (96 pages)
- 3296M - IOM (92 pages)
- 3298 - IOM (120 pages)
- 3311 - IOM (44 pages)
- 3316 - IOM (36 pages)
- 3335 - IOM (40 pages)
- 3355 - IOM (66 pages)
- 3393 - IOM (124 pages)
- 3408 - IOM (78 pages)
- 3408A - IOM (44 pages)
- 3409 - IOM (68 pages)
- 3410 - IOM (56 pages)
- 3420 - IOM (120 pages)
- 3498 - IOM (59 pages)
- 3500XD - IOM (44 pages)
- 3501 Mixer - IOM (48 pages)
- 3600 - IOM (110 pages)
- 3620 - IOM (98 pages)
- 3640 - IOM (98 pages)
- 3642 - IOM (12 pages)
- 3675 - IOM (12 pages)
- 3700 - IOM (110 pages)
- 3755 - IOM (32 pages)
- 3796 i-FRAME - IOM (134 pages)
- 3910 11th ed. - IOM (80 pages)
- 3935 - IOM (24 pages)
- 3996 - IOM (52 pages)
- 4550 - IOM (36 pages)
- 5000 - IOM (24 pages)
- 5100 - IOM (28 pages)
- 5150 - IOM (28 pages)
- 7200CB - IOM (132 pages)
- ANSI FAMILY IOM (ATEX Compliant) (56 pages)
- ANSI FAMILY IOM (ATEX Compliant) (27 pages)
- ANSI FAMILY IOM (ATEX Compliant) (42 pages)
- ANSI FAMILY IOM (ATEX Compliant) (45 pages)
- Pump Safety (9 pages)