Commissioning, Startup, Operation, and Shutdown

f)

Replace the coupling hub (if removed) and the spacer portion of the coupling.
Refer to the instructions from the coupling manufacturer for assistance.

Complete any coupling adjustments before you proceed with the coupling guard assembly.

2. Slightly spread the opening of the coupling guard half and place it over the pump end plate.

1. Pump half of the coupling guard
2. Annular groove
3. Deflector fan guard
4. Driver

The annular groove in the guard is located around the end plate.
Position the opening (flange) so that it does not interfere with the piping but still allows for
access when you install the bolts.

1. Annular groove
2. Deflector fan guard
3. Coupling guard half

Installation, Operation, and Maintenance Manual