Commissioning, Startup, Operation, and Shutdown

1. Float switch
2. Suction gate valve
3. Vent plug
4. Discharge gate valve

Figure 11: Suction supply above the pump

Prime the pump with an outside supply

This method ensures that the pump will remain primed if the foot valve is tight. If the foot valve
fails when the pump is standing idle, then the pump will lose its prime. During long idle periods,
the pump can also lose its prime through leakage from the stuffing boxes.
1. Close the discharge gate valve, remove the vent plug, and open the valve in the priming

supply line until all air is expelled and water comes out of the vent openings.

2. Close the air vents, close the valve in the priming supply line, and start pump.
3. Open the discharge gate valve.

1. From outside supply
2. Shutoff valve
3. Vent plug
4. Discharge gate valve
5. Foot valve

Figure 12: Prime with an outside supply