beautypg.com

Install the pump, driver, and coupling, Pump-to-driver alignment – Goulds Pumps 3610 - IOM User Manual

Page 22

background image

Installation

2. Adjust the leveling jackscrews, located adjacent to the foundation bolt holes, until the

baseplate rests 1 to 2 in. (25 to 50 mm) above the foundation in order to allow for adequate
grouting.
This provides even support for the baseplate after grouting.

3. Level the baseplate to within 0.002 in./ft. (0.167 mm/m) of the length or width of the

baseplate by adjusting the jackscrews.

• The maximum total variation from one end or side of the baseplate to the other is

0.015 in. (0.38 mm).

• Use the equipment mounting surfaces in order to establish the level.

4. Use a non-bonding (anti-seize) compound such as paste wax to coat the portions of the

jackscrews that will contact the grout.
This facilitates removal of the screws after grouting.

NOTICE:
Do not use oils or liquid wax.

5. Thread the nuts onto the foundation bolts and hand-tighten.

Install the pump, driver, and coupling

1. Mount and fasten the pump on the baseplate. Use applicable bolts.
2. Mount the driver on the baseplate. Use applicable bolts and hand tighten.
3. Install the coupling.

See the installation instructions from the coupling manufacturer.

Pump-to-driver alignment

Precautions

WARNING:

• Follow shaft alignment procedures in order to prevent catastrophic failure of drive components or

unintended contact of rotating parts. Follow the coupling installation and operation procedures from
the coupling manufacturer.

• Always disconnect and lock out power to the driver before you perform any installation or

maintenance tasks. Failure to disconnect and lock out driver power will result in serious physical
injury.

NOTICE:
Proper alignment is the responsibility of the installer and the user of the unit. Check the
alignment of frame-mounted units before you operate the unit. Failure to do so can result in
equipment damage or decreased performance.

Alignment methods

Three common alignment methods are used:

• Dial indicator

• Reverse dial indicator

• Laser

Follow the instructions from the equipment manufacturer when you use the reverse dial
indicator or laser methods. Detailed instructions for using the dial indicator method are
contained in this chapter.

20