Solstice I12+ Cooking Computer for ROV Fryers
Pitco P/N 60149517 & 60149518
L20-414 Rev 2
Page 26 of 32
8.11.2 Maximum JIB Time
This adjustment selects the
amount of oil in terms of “pump time” for a full JIB. Factory default
– 1:30.
With display showing
, press product key [2].
Display shows
, where m:ss is the time the reset value
for a new JIB.
To change this value, use the product keys for numeric entry of a new value. Acceptable
entry range is 0:00 to 4:00.
Press the
key to save entry.
Display returns to
.
8.11.3 Low JIB Time
This adjustment selects the
amount of oil remaining in terms of “pump time” for a low JIB.
Factory default
– 0:20.
With display showing
, press product key [3].
Display shows
, where m:ss is the time remaining when
“LOW JIB” is displayed.
To change this value, use the product keys for numeric entry of a new value. Acceptable
entry range is 0:00 to 4:00.
Press the
key to save entry.
Display returns to
.
8.11.4 JIB Monitor (Check/Fault) Enable
This selection allows the enabling and disabling of the JIB monitor for error conditions
feature.
With display showing
, press product key [4].
Display shows
, where xxx is either ON or OFF.
Use product key [0] change value. Press the
to save choice.
Display returns to
.
8.11.5 Filter Return Key Enable
This selection allows the enabling and disabling of the Filter Return key for manual filter
configurations.
With display showing
, press product key [5].
Display shows
, where xxx is either EN or DIS.
Use product key [0] change value. Press the
to save choice.