8.6

Cook Counts Allowed:

This adjustment selects the number of cooks allowed before FILTER SOON is displayed to
the operator. Factory default: Full

– 10, Split – 5.

With display showing

, press product key [6].

Display shows

, where nn is the

number of cooks allowed before recommended filtering.

To change this value, use the product keys for numeric entry of a new
value. A value of 0 will disable Cook Filter Lockout.

Press the

key to save entry. Display returns to

.

8.7

Cook Counts Deferred:

This adjustment selects the number of defers allowed before FILTER NOW is displayed and
additional cooks are prohibited. The total number of cooks allowed after a filter event is the
sum of Cook Counts Allowed and Cook Counts Deferred. Factory default

– 2.

With display showing

, press product key [7].

Display shows

, where nn is the

number of defers allowed before forced filtering.

To change this value, use the product keys for numeric entry of a new
value. A value of 0 will not prevent operator from preforming additional
cooks once the Cook Counts Allowed value has been reached.

Press the

key to save entry. Display returns to

.

8.8

Oil Level Probe/Auto Top-Off Enable:

This selection allows the enabling and disabling of the Auto Top-Off feature.

With display showing

, press product key [8].

Display shows

, where xxx is either ON or OFF.

To change this value, use product key [0] to toggle between ON and
OFF.

Press the