8.3

Polish Time:

This adjustment controls the oil cycle time for filter operation POLISH. This value should be
selected to allow oil to make multiple passes through the filter pan. Factory default

– 30:00.

With display showing

, press product key [3].

Display shows

, where m:ss is the time

the vat will polish.

To change this value, use the product keys for numeric entry of a new
value. Acceptable entry range is 00:00 to 99:59.

Press the

key to save entry. Display returns to

.

8.4

Fill Time:

This adjustment controls the vat fill time for auto-filter operations FILTER and POLISH. This
value should be selected to allow adequate time for the filter pan to be completely emptied
and return lines cleared of oil. Factory default: Full

– 1:15, Split – 0:45.

With display showing

, press product key [4].

Display shows

, where m:ss is the time

the vat will fill.

To change this value, use the product keys for numeric entry of a new
value. Acceptable entry range is 0:30 to 4:00.

Press the

key to save entry. Display returns to

.

8.5

Filter Temperature:

This adjustment selects the minimum oil temperature allowed for auto-filter operations to be
initiated. Manual filter operations are unaffected by this value. Factory default

– 275 °F.

With display showing

, press product key [5].

Display shows

, where nnn is the

minimum oil temperature autofilter operations can be performed, and
where X is F (Fahrenheit) or C (Celsius).

To change this value, use the product keys for numeric entry of a new
value.

Press the

key to save entry. Display returns to

.