Solstice I12+ Cooking Computer for ROV Fryers

Pitco P/N 60149517 & 60149518

Page 19 of 32

L20-414 Rev 2

7

To Change Options Level 2 ( for the Store Manager):

The display must show

from section 2 to change these options. When the

product key [0] is pressed, the display will show

. Indicator

lights above product keys will illuminate to represent options that may be changed. Each
option listed below uses the product key [0] to toggle or scroll through available choices in the

display. When the correct value is displayed, press the

key to save choice. The

display will again return to

for another option selection.

7.1

Fahrenheit or Celsius Display:

The Controller will display temperatures in the Fahrenheit or Celsius scales. The default scale is °F.
With display showing

, press the product key [10/0].

Display shows

.

Press product key 1, display shows [DEGREE n] [

F OR C], where “n” is the current

setting.

Use the product key [0] to scroll through choices (F or C). Press

key to save

choice.

Display shows

.

7.2

Password Change or Required:

With factory settings, an operator password is not required to enter programming Levels 1 and 2.
The password may be activated or changed in these steps.

With display showing

, press the product key [0].

Display will show

.

Press product key 2, display shows [SET PAS] [NEW PASS]. Use the product key [0] to

scroll through choices [NO PASS] or [PASS REQ]. Press

key to save choice.

If [NO PASS] is selected Display returns to

.

If [PASS REQ]. is selected, display will show [PASSnnnn] [NEW PASS] to prompt for new
password. Displayed value “nnnn” is the current password. Use the product keys for numeric
entry to change password. Press [P] key to save choice. Display then shows

.

Note: The factory default password (6684) will always work even if a different password is selected

here.