beautypg.com

Pitco Frialator I12+ Cooking Computer for ROV Fryers User Manual

Page 13

background image

Solstice I12+ Cooking Computer for ROV Fryers

Pitco P/N 60149517 & 60149518

Page 13 of 32

L20-414 Rev 2

2.4.6

Right Manual Top-Off (Split Vat Only):

While in the advanced oil handling menu, press product key [5].

Display shows

.

Press and hold product key [5] to manually add fresh oil to the vat.

Display will show

while product key [6]

is held down.

Release product key [6] to stop adding fresh oil.

Press key

to exit the menu or select a product key [L-5] to

perform another action.

3

Control Filter Lockout (CFL):

This computer includes the Cook Count-based Control Filter Lockout (CFL) function which enforces
operator compliance with regularly scheduled filtering based on the number of cooks performed
since the last filter.

Performing any automated oil filter operation will reset the cook counter. Also, any manual
operation that includes the opening of the drain valve for 20 seconds or more will also reset the
cook counter. The cook counter may be reset at any time, where the computer does not have to
be in a Filter Soon or Filter Now state.

To check the current remaining cooks available before Filter Lockout, press the

key until

the Cooks Remaining message

is shown. Press the

key again to show

the maximum number of cooks allowed

.

3.1

Filter Soon:

Filter Soon message

will show when the number of cooks since the last filter

operation is greater than the Cook Counts Allowed value (section 8.6). It is suggested to
perform a filter operation when business levels permit.

The

message will not be viewable if there are active cook timers.

Additional cooks are allowed when in Filter Soon state.

3.2

Filter Now:

Filter Lockout messages

or

will show on the

displays when the number of cooks since the last filter operation is equal to the sum of the
Cook Counts Allowed value and the Cook Counts Deferred value (section 8.7). It is required to
perform a filter operation at this time.

The

message will display when the final allowed cook has been

completed. Perform the required filtering when this cook completes.

When in the Filter Lockout state, cooks are no longer allowed and product key presses
are ignored.