Commissioning remote control, 1 selecting the setup location, 2 installation – Karcher IV 100 - 55 M B1 User Manual
Page 30: 3 functional description, 4 parameter iv vacuum cleaner control, 17 commissioning, Remote, Control, 3 functional, Description
![background image](/manuals/433217/30/background.png)
30
English 5.906-587.0 Rev. 00 (05/14)
Make sure that a suitable power supply is available in the
immediate vicinity (see technical data of the vacuum
cleaner).
Note
–
The scope of delivery does not include any fastening
material!
–
The fastening material must be adapted to the local
consistency and condition of the wall and must be or-
dered separately.
–
You will need:
4 x suitable fasteners with a load of 0.5 KN per dowel
and a pin diameter of max. 6 mm.
Remove the remote control from its packaging and
check for completeness.
Mount remote control onto a suitable wall.
Connect the electric supply line via a CEE plug (DIN
49462/63) or a terminal box. (This work must be per-
formed by a skilled and authorised electrician)
Mount and connect the starting devices (push button,
switch, coin acceptor, etc.)
Set the parameters.
–
Remote control cabinet (No. 4.812-236.0) for the con-
nection of vacuum cleaners up to max. 7.5 KW via 230V,
CEE 16A 400V and CEE 32A 400V connections associ-
ated with four external start options.
A soft start can be optionally installed.
–
Via the SPS menu various switching types can be select-
ed.
–
Inching:
Press 1 x, vacuum cleaner is running, lamp is flashing.
Press again, the vacuum cleaner switches off and the
lamp goes out.
–
Inching:
Press 1 x, vacuum cleaner is running, lamp is flashing.
After the set time under the parameters B20 to B30, the
vacuum cleaner switches off.
–
Switching operation:
The vacuum cleaner runs as long as the switch is on
"ON".
–
The "Lamp" signal can also be used for switching valves
or the like, for this purpose the parameters B129 to B135
must be changed accordingly.
–
Via the parameter B33 a maximum run time can be
specified to avoid cycling in case of a failure to switch off.
–
Via the parameter B137 it is selected whether a soft start
is installed or not.
–
In order to ensure that after closing all valves or slides
the suction pipe was sucked free, an after-running time
can be set via the parameter B143.
CAUTION
When using the "after-running time" function, a false air
flap must be installed to avoid an excessive vacuum in the
system.
A detailed description can be found in the operating in-
structions of the remote control 5.965-276.0.
17 Commissioning remote control
17.1 Selecting the setup location
17.2 Installation
17.3 Functional description
17.4 Parameter IV vacuum cleaner control
B20
With preselection "pushbutton" run time vacuum
cleaner station 1
B 28
With preselection "pushbutton" run time vacuum
cleaner station 2
B 29
With preselection "pushbutton" run time vacuum
cleaner station 3
B 30
With preselection "pushbutton" run time vacuum
cleaner station 4
B 33
Maximum run time vacuum cleaner all stations
are switched off
B 49
To FB 1 =
0: Button
1: Switch
B 50
To FB 2 =
0: Button
1: Switch
B 51
To FB 3 =
0: Button
1: Switch
B 52
To FB 4 =
0: Button
1: Switch
B 65
Reset daily operating hours counter:
Can be reset via password (1234) or button <-
and -> held down for 2 seconds.
B 129 Lamp connected
station 1
1= lamp
0 = valve
(no flashing
with run time)
B 131 Lamp connected
station 2
1= lamp
0 = valve
(no flashing
with run time)
B 133 Lamp connected
station 3
1= lamp
0 = valve
(no flashing
with run time)
B 135 Lamp connected
station 4
1= lamp
0 = valve
(no flashing
with run time)
B 137 Soft start yes / no
1 = soft
start in-
stalled
0 = no soft
start installed
B 143 After-running time vacuum cleaner