Make sure that a suitable power supply is available in the
immediate vicinity (see technical data of the vacuum
cleaner).

Note

The scope of delivery does not include any fastening
material!

The fastening material must be adapted to the local
consistency and condition of the wall and must be or-
dered separately.

You will need:
4 x suitable fasteners with a load of 0.5 KN per dowel
and a pin diameter of max. 6 mm.

Remove the remote control from its packaging and
check for completeness.

Mount remote control onto a suitable wall.

Connect the electric supply line via a CEE plug (DIN
49462/63) or a terminal box. (This work must be per-
formed by a skilled and authorised electrician)

Mount and connect the starting devices (push button,
switch, coin acceptor, etc.)

Set the parameters.

Remote control cabinet (No. 4.812-236.0) for the con-
nection of vacuum cleaners up to max. 7.5 KW via 230V,
CEE 16A 400V and CEE 32A 400V connections associ-
ated with four external start options.
A soft start can be optionally installed.

Via the SPS menu various switching types can be select-
ed.

Inching:
Press 1 x, vacuum cleaner is running, lamp is flashing.
Press again, the vacuum cleaner switches off and the
lamp goes out.

Inching:
Press 1 x, vacuum cleaner is running, lamp is flashing.
After the set time under the parameters B20 to B30, the
vacuum cleaner switches off.

Switching operation:
The vacuum cleaner runs as long as the switch is on
"ON".

The "Lamp" signal can also be used for switching valves
or the like, for this purpose the parameters B129 to B135
must be changed accordingly.

Via the parameter B33 a maximum run time can be
specified to avoid cycling in case of a failure to switch off.

Via the parameter B137 it is selected whether a soft start
is installed or not.

In order to ensure that after closing all valves or slides
the suction pipe was sucked free, an after-running time
can be set via the parameter B143.

CAUTION
When using the "after-running time" function, a false air
flap must be installed to avoid an excessive vacuum in the
system.
A detailed description can be found in the operating in-
structions of the remote control 5.965-276.0.

17 Commissioning remote control

17.1 Selecting the setup location

17.2 Installation

17.3 Functional description

17.4 Parameter IV vacuum cleaner control

B20

With preselection "pushbutton" run time vacuum
cleaner station 1

B 28

With preselection "pushbutton" run time vacuum
cleaner station 2

B 29

With preselection "pushbutton" run time vacuum
cleaner station 3

B 30

With preselection "pushbutton" run time vacuum
cleaner station 4

B 33

Maximum run time vacuum cleaner all stations
are switched off

B 49

To FB 1 =

0: Button

1: Switch

B 50

To FB 2 =

0: Button

1: Switch

B 51

To FB 3 =

0: Button

1: Switch

B 52

To FB 4 =

0: Button

1: Switch

B 65

Reset daily operating hours counter:
Can be reset via password (1234) or button <-
and -> held down for 2 seconds.

B 129 Lamp connected

station 1

1= lamp

0 = valve
(no flashing
with run time)

B 131 Lamp connected

station 2

1= lamp

0 = valve
(no flashing
with run time)

B 133 Lamp connected

station 3

1= lamp

0 = valve
(no flashing
with run time)

B 135 Lamp connected

station 4

1= lamp

0 = valve
(no flashing
with run time)

B 137 Soft start yes / no

1 = soft
start in-
stalled

0 = no soft
start installed

B 143 After-running time vacuum cleaner