5 step 5, 6 step 6, 5 step – Karcher IV 100 - 55 M B1 User Manual
Page 19: 6 step
English 5.906-587.0 Rev. 00 (05/14)
19
Calculation of the pressure losses in the sections:
Note
All sections together reveal the entire pressure loss plus
10-20% security.
Example:
Alignment of the overall pressure loss with the vacuum
cleaner characteristic.
Example:
With a pressure loss performance of 128 mbar, a volume
flow of ~330 m³/h remains with IV 100/55.
11.5 Step 5
Section
Suction hose Lengt
h
Component
Flow speed
Pressure loss
1
DN 80
25 m
3x Y-pieces
2x 90° bends
27.63 m/s
32.63 mbar
2
DN 60
5 m
24.56 m/s
6.03 mbar
3
DN 51
5 m
1x custom component
(Suction hose)
35.37m/s 18.01 mbar
110.94 mbar + 15% security addition = ~128 mbar
11.6 Step 6