ADTRAN ISU 512 User Manual
Page 72

Chapter 5: Configuration
56
ISU 512 User Manual
61202.086L1-1
CONFIGURING THE ISU 512 FOR V.25 BIS IN-BAND DIALING
V.25 bis dialing is used primarily by data terminal equipment with synchro-
nous interfaces (HDLC/SDLC or BSC/BISYNC) not supporting the AT com-
mand set, which is commonly used by asynchronous devices. The ISU 512
supports V.25 bis in-band dialing in accordance with Fascicle VIII.I - V.25 bis
(Malaga-Torremolinos 1984, Melbourne 1988).
Recommendation V.25 uses the following DCE/DTE control signals:
Transmitted data
Circuit 103
Received data
Circuit 104
Ready for sending
Circuit 106
Data set ready
Circuit 107
Data terminal ready
Circuit 108/2
Calling indicator
Circuit 125
The ISU 512 supports the following V.25 bis commands to control automatic
calling and answering:
CRN
Call request (number in command)
CRS
Call request (using stored number)
PRN
Program stored number
RLN
List stored number
CIC
Connect incoming call
DIC
Disconnect incoming call
When using stored numbers, V.25 bis accesses stored numbers 1 through 9 used by
front panel dialing. See Dialing Options (in this chapter).
Auto answer should be disabled if V.25 bis is in control of answering incoming calls
with the CIC/DIC commands, since the other settings for Auto answer will override
V.25 control of the answer function.