Electrical Specifications

30 Pound Capacity Models

Voltage Designation

Standard

Electric Heat

Co
de

Vo
lta

g

e

Cy
cl

e

Phase

Wir
e

Full Lo

ad

Amp

s

Circuit

Br

eak

er

AW
G

mm

2

Full Lo

ad

Amp

s

Circuit

Br

eak

er

AW
G

mm

2

2 Speed Models

C

380 – 415

50

3

4

4

15

14

2.5

15

20

12

4.0

F

440 – 480

60

3

3

4

15

14

2.5

16

20

12

4.0

J

200

50

3

3

7

15

14

2.5

N/A

O

208 – 240

60

3

3

7

15

14

2.5

25

30

10

6.0

Y

208 – 240

60

1

2

10

20

12

4.0

N/A

Variable-Speed Models

Q

200 – 240

50/60

3

3

5

15

14

2.5

22

30

10

6.0

R

(through

7/6/10)

380 – 480

50/60

3

3

4

15

14

2.5

N/A

N

(starting

7/7/10)

440 – 480

60

3

3

4

15

14

2.5

N/A

P

(starting

7/7/10)

380 – 415

50/60

3

3

4

15

14

2.5

14

15

14

2.5

X

200 – 240

50/60

1/3

2/3

7/5

15

14

2.5

N/A

NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.