Installation

F8208301

44

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Electrical Installation Requirements

IMPORTANT: Electrical ratings are subject to

change. Refer to serial decal for electrical ratings

information specific to your machine.

Electrical connections are made at the rear of the

machine. The machine must be connected to the

proper electrical supply shown on the identification

plate attached to the rear of the machine, using copper

conductors only.

IMPORTANT: Alliance Laundry Systems

warranty does not cover components that fail as a

result of improper input voltage.

Make sure the correct transformer jumper (208 Volt or

240 Volt) is in place. Refer to the “optional” Electrical

Service Connection label located on the back of the

machine near the electrical service input for machine

electrical requirements. Refer to Figure 27.

Figure 27

Machines equipped with an AC inverter drive require

a clean power supply, free from voltage spikes and

surges. Use voltage monitor to check incoming power.

The customer’s local power company may provide

such a monitor.

Hazardous Voltage. Will cause shock,

burn or death. Allow machine power to

remain off for three minutes prior to

working in and around AC inverter drive.

W735

DANGER

Dangerous voltages are present inside

the machine. Only qualified personnel

should attempt adjustments and

troubleshooting. Disconnect power from

the machine before removing any cover

and guards, and before attempting any

service procedures.

W736

WARNING

Hazardous Voltage. Can cause shock,

burn or death. Verify that a ground wire

from a proven earth ground is connected

to the lug near the input power block on

this machine.

W360

WARNING

CHM2287N

1

Electrical Service Connection Label

1