Chapter 22: RMON

290

Port Statistics

You can remotely view individual port statistics with RMON by using your
SNMP NMS software and the RMON portion of the MIB tree.

Perform the following procedure to configure RMON port statistics for a
specific port:

1. From the main menu on the left side of the page, click the RMON

folder.
The RMON folder expands.

2. From the RMON folder, select Statistics.

The Ethernet Statistics Configuration Page is displayed. See
Figure 103.

Figure 103. Ethernet Statistics Configuration Page

3. The following fields are listed:

Index - This parameter specifies the ID number of the new group.
The range is 1 to 65535.

Port - This parameter specifies the port where you want to monitor
the statistical information of the Ethernet traffic.

Owner - This parameter is used to identify the person who created
an entry. It is primarily intended for switches that are managed by
more than one person, and is an optional field.

4. Once you have configured the parameters, click Add.

Your entry will appear in the table at the bottom of the page.

5. If you want to configure RMON statistics for other ports,

repeat steps 3 and 4.

6. From the main menu on the left side of the page, select Save