Snmpv1/v2 community strings, Create snmpv1/ v2 community strings, Create snmpv1/v2 community strings – Allied Telesis AT-GS950/8 User Manual
Page 269
AT-GS950/8 Web Interface User Guide
269
SNMPv1/v2 Community Strings
A community string has attributes for controlling who can use the string
and what the string will allow a network management station to do on the
switch.
The AT-S107 Management software does NOT provide any default
community strings. You must first define an SNMP User and Group Name
on the SNMP User/Group page and then define a Community Name on
the SNMP Community Table page.
Create SNMPv1/
v2 Community
Strings
1. From the main menu on the left side of the page, select the SNMP
folder.
The SNMP folder expands.
2. From the SNMP folder, select Community Table.
The Community Table Page is displayed. See Figure 96.
Figure 96. Community Table Page
3. Enter a new Community Name.
Enter a name up to 31 characters in length.
4. Enter a User Name(View Policy) that has been previously defined.
Note
This name must be the same as one of the User Names displayed
on the SNMP User/Group page - see “Create SNMP v1/v2 User
and Group Names” on page 267. If you enter a user name that has
not been pre-defined on the SNMP User/Group page, the
Community entry will be displayed, but the agent/manager
communication will fail.