beautypg.com

6 conductor information – Cirrus Logic CobraNet User Manual

Page 79

background image

CobraNet Programmer’s Reference

Management Interface Variable Reference

DS651PM25

©

Copyright 2006 Cirrus Logic, Inc.

79

6.4.6 Conductor Information

These conductor variables give a description and status of the current conductor of the
CobraNet network.

Name

condInfoPriority

Description

Conductor priority of the current conductor.
1 - Lowest conductor priority
255 - highest conductor priority
If the priority of the current conductor is adjusted,

condInfoPriority will change to reflect this.

Dependent on priority setting of other devices on the network, a change in current conductor priority
does not necessarily induce a change in conductor and

condInfoMAC.

Host Address

0x11001

SNMP Object ID

1.3.6.1.4.1.2680.1.1.4.5

Type

Integer

Attributes

Read-only

Implemented Version

2.9.12 (24-bit platforms only.) Not available on 32-bit patforms.

Name

condInfoMAC

Description

Ethernet MAC address of the current conductor.
condInfoMAC should read 00:00:00:00:00:00 if there is no conductor on the network. There is no
conductor if there is 0 or 1 CobraNet device(s) attached to the network or if all CobraNet devices
have a condPriority setting of 0.

Host Address

0x11002

SNMP Object ID

1.3.6.1.4.1.2680.1.1.4.6

Type

Physical Address

Attributes

Read-only

Implemented Version

2.9.12 (24-bit platforms only.) Not available on 32-bit patforms.

Name

condInfoLastChange

Description

sysUpTime value at time of last change to condInfoMAC.

Host Address

0x11005

SNMP Object ID

1.3.6.1.4.1.2680.1.1.4.7

Type

Time Ticks

Attributes

Read-only

Implemented Version

2.9.12 (24-bit platforms only.) Not available on 32-bit patforms.